INSTRUCTION MANUAL
20221487 / B 13
3.5 Commissioning
Perform the following tests when commissioning the repeater:
7 Ensure that the mechanical installation and cable
connection has been completed according to the
description on previous pages
8 Connect the cable to the repeater. The repeater will
automatically sense which digital signal that is present
- The repeater will align itself to zero and then to the
transmitted gyro heading
9 Ensure that the lighting is set to a suitable level. Adjust if
necessary with the dimmer button
3.6 Fault finding
The AR68/AR77 are sealed units, and breakage of the security
seal will invalidate the warranty.
If trouble is encountered, make preliminary checks as described
below. If the problems remain unsolved, contact your nearest
Simrad dealer for assistance.
Symptom Probable fault Remedy
The repeater does not
operate.
No power or incorrect power
connection.
Check incoming power
supply.
The repeater aligns itself
to zero and does not
respond to heading
input.
The dial rotates +/- 35°.
The digital signal to the repeater is
either not present, or the sentence
being sent is incorrect or has wrong
polarity.
Switch the unit off and on
again.
Lighting not visible Damage to internal LED, or
damage to internal PCB.
Return to Simrad dealer for
service.