Instruction manual
15
857-164777 / A
$PSIMTH,x.x,M,y.y,M*hh<cr><lf>
Trawl Headrope to Footrope and Bottom (Trawl Eye/Height sensor 1)
TH represents the distances from the Headrope to the Footrope and
Bottom.
x.x,M is the distance in metres from hea drope to footrope (0 - 100 m).
y.y,M is the distance in metres from headrope to bottom (0 - 100 m).
$PSIMTE,xx%y,xx%y,xx%y,xx%y,xx%y,xx%y,xx%y,xx%y,xx%y,xx%y,a,x.x,M ,
Gx,gx,Vx.x *hh< cr><lf> Trawl Eye, Echo telegram, fish detection
TE carries the echo readings from fish detection and the sensor set
up parameters (type of trawl, range gain etc).
x.x% per ce nt of samples above t hreshold for the 10 echo cells.
y average level (1-7) of the xx %. Data skipped if cell is empty or
not available.
a B/P Bottom/Pelagic 10 cells. b/p: bottom/pelagic 5 cells.
x.x,M total range, 2,5 50 m of fish detection range.
Gx Gain setting, coarse.
gx g1 g7 gain setting fine.
Vx.x Version of Trawl Eye Sensor software.