Seitenansicht 116
Cablelayoutandinterconnections
Transducercablesoverview
Atotalof25transducercablesarebroughtupfromthetransducerarray.Eachcableis
terminatedinalargeconnector,andeachconnectorplugsintoitsdedicatedsocketon
therearsideoftheTRXUtransceiversubracks.Thetransducercablesareidentied
withnumbers001through025
AlltransducercablesareprovidedbyKongsbergMaritime.
Relatedtopics
Transducercablesonpage156
TerminationstoTRXU0(Topsubrack)onpage158
TerminationstoTRXU1(Middlesubrack)onpage159
TerminationstoTRXU2(Bottomsubrack)onpage160
Transducercablesonpage115
Transducercables
TheMS70transducerarrayisorganisedasfollows:
Thearraycontains25quadrants
Eachquadrantcontains32individualelements
EachquadrantisconnectedbymeansofaseparatecabletoadedicatedTRX32circuit
boardhandlingthe32channels
Transducercablepairs
Thereare36cablepairsineachtransducercable.
32ofthesecablepairsareusedfortheelementsinthemodule.
Cablepair33connectstoathermistoronthetransformercircuitboardinthetransducer.
Thelasttwocablespairsarenotused,andthesearecut.