Simrad TRANSDUCER - INSTALLATION GENERIC REV H Installationshandbuch Seite 41

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 212
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 40
Transducerinstallation
Headingsensor
Thealignmentofthemotionsensorandtheheadingsensormustbeadjustedsothatthey
providezerovaluesforpitch,rollandheadingwiththevessellyingstillwithnormal
trimandatrueNorthheading.Itisrecommendedthatthistakesplaceinthedrydock.
Alternatively,theoffsetsfromzeromustbedetermined.Thisiseasiesttodowiththe
vesselberthed.Followtheproceduresintheapplicablesensormanuals.
Note
Theheadingsensormustbealignedwiththevesselcentreline.
Measurementaccuracy
Therequiredmeasurementaccuraciesgivenbelowhavebeendeterminedfrom
considerationsonhowtheycontributetototalsystemaccuracy.Anyerrorsinthese
measurementsshallnotsignicantlycontributetodepthorpositionerrorsinthe
soundings.
Themotionsensormustbealigned(setup).Theindicatedrollandpitchanglesfromthe
sensorwhenthevesselhasanormaltrim(i.e.thecoordinatesystem’shorizontalplaneis
horizontal)mustbelessthan±0.055°forbothrollandpitch.
Note
Thegivenaccuraciesaremaximumvalues,andifeasilyachievable,betteraccuracies
shouldbeobtained.
331549/B