Adjustingi.
the, iddle position switch
Normally, when the transducer is selected to middle position on
the Sonar Control Unit
, only one half of the transducer
face
should be outside the sonar
trunk (see figure 5). The middle
position switch
, which is a magnetic switch, must then be
adjusted according to the
trunk length:
With the Hull
Unit fully
hoisted to upper position
measure the
distance x between the bottom of the
transducer and the trunk end.
See the lower part of figure
~X= mm
Ifit is impossible to measure the
distance x, it can be
calculated
by using the total trunk height D from page 12 in section
Installation procedures
" .
Total
trunk height D =
- Distance flange/transducer bottom =
760 mm
= Distance X
Use the hoistingllowering switch in the
motor control
unit to position the transducer in the
calculated correct
position x + 240 mm (see figure 5).
Loosen the bracket for the middle
p~sition switch and
align the switch relative to the magnet as shown on figure
5. Ifneeded
, spare cable is coiled up behind the bracket.
Fasten the bracket and check that the distance
between
the magnet and the switch is approximately 5-
8 mm.
Check the passing of the middle position switch by using
the hoistingllowering switch.
Use the hoistingllowering switch to hoist the Hull Unit to
its upper position.
Release the motor overload switch S301 by pressing the
red button marked " . This to prevent
unwanted
lowering of the transducer.