Installation procedures
27
851-160572 / B
Connecting auxiliary equipment
General
It is not necessary to make the connection of the auxiliary
equipment before the start-up procedure is finished, and this
equipment may therefore be connected later. Anyhow, do not
connect the plugs for the auxiliary equipment to the Sonar
Control Unit before mentioned in a later chapter.
The SP270 sonars require connection of a speed log and a
course gyro. An inaccurate log or gyro input will cause
inaccurate indication of the vessel and target movements.
Speed log
• Pulse log: 100, 200 or 400 pulses/nm.
• Serial line, standard NMEA 0183; RS232, RS422 or Current
loop.
Course gyro
• 3-phase synchro signal, 20-220V L-L, 50/60/400Hz
Gear ratio 1:360, 1:180, 1:90, 1:36.
• 3-phase stepper signal, 20-220V L-L.
Gear ratio 1:360, 1:180, 1:90, 1:36.
• Serial line, standard NMEA 0183; RS232, RS422 or Current
loop.
Echo sounder
In order to get a depth indication on the catch control page on
the sonar, one of the following Simrad echo sounders can be
connected:
• EQ50, EQ100, ES380 Series, ES500 (RS-232 serial line).
Trawl system
In order to get the trawl information on the sonar display, one of
the following Simrad trawl systems can be connected:
• FS Trawl sonar (RS-232 serial line or 20mA current loop).
• ITI Integrated Trawl Instrumentation (RS-232 serial line).
Connecting the course gyro
The Sonar Control Unit can be connected to a course gyro with
one of the following outputs (tick off for the type which will be
connected):
• 3-phase synchro signal
• 3-phase stepper signal
• Serial line (NMEA 0183)