Simrad SP 270
Starting,
u;p.
.the+.
stand~
by power su pply
In order to start up the sonar units
, the 24 VDC stand-by power
supply in the Transceiver Unit has to be
started up first. Refer
to figure 1 and use the
following procedure to start
up the
stand-by power supply:
Check that the mains
input connector P201 on the front
of the power
supply in the
Transceiver Unit
disconnected.
Check that the switch S202 on the front of the power
supply is set to OFF (middle) position.
Insert the mains fuses to the
Transceiver Unit on the
ship s mains switchboard.
Measure the mains voltage supplied to the Transceiver
Unit.
Write the measured voltage here...................
VAC.
Check if the voltage selector switches S201 on the power
supply and S203 on the HV power unit correspond to the
measured voltage (115V or 230V position).
Reinsert the mains input connector
P201 on the front of
the power supply.
Check that the lamps L201 and L202 on the front
of the
power supply illuminate.
Check that the small LED (Light Emitting Diode) for the
+24V stand-
by power on the
Transceiver Interface Board
(TIB) illuminates (refer to indication on
the front of the
power supply).
Now the 24 VDC stand-by power is supplied both to the Hull
Unit and to the
connector for the Sonar Control Unit.