20
851-160571 / B
Technical specifications
Table 1 comprises the specifications required for the installation.
For further details, refer to the Operator Manual.
Sonar Control
Unit
Transceiver Unit Hull Unit
Voltage, nominal 115/230VAC
Single phase*
115/230 VAC
Single phase**
230/380/440 VAC
3--phase***
Voltage deviation 15% of nominal 15% of nominal 230V:15%
380/440V:
340 -- 485V
Voltage transient 20% of nominal
recovery time 3s
20% of nominal
recovery time 3s
20% of nominal
recovery time 3s
Power consump-
tion
100 VA 600 VA 750 VA max.
Frequency 47 -- 63 Hz 47 -- 63 Hz 47 -- 63 Hz
Temp.: Storage
Operating
-- 4 0 t o + 7 0 °C
0to+40°C
-- 4 0 t o + 7 0 °C
0to+40°C
-- 2 0 t o + 7 0 °C
0to+40°C
Humidity 5--95% relative
non--condensing
5--95% relative
non--condensing
5--96% relative
non--condensing
Refer to the voltage, nominal line in table 1.
* Input voltage is automatically selected.
** Input voltage is selected with two switches.
*** Input voltage is selected on the motor connections
Weights and dimensions
The table below shows the weights for the different units of the
sonar, and a reference for the figures showing the outline
dimensions of the units.
Weight Dimensions
Sonar Control Unit 25 kg Seefigure2
Control Unit without display 10 kg Seefigure3
Transceiver Unit 75 kg Seefigure4
Hull Unit 530 kg Seefigure5
Trunk (optional) 68 kg Seefigure6