Simrad SP270
22
851-160572 / B
Sonar Control Unit cabling
All the cables to the Sonar Control Unit are to be plug connected
to the electronic drawer unit at the rear of the cabinet (see figure
13). The numbers on the figure refer to the cable numbers on the
cable plan.
Note In order t o make service on the Sonar Control Unit, the cables
must have a slack so the electronic drawer unit can have all the
cables connected while it is outside the cabinet. This could be
either by pulling it out from the front, or by reconnecting t he
cables with the drawer at floor level.
3
1
2
4
115/230V AC mains
S101
Transceiver
Course gyroSpeed log
GND
N L
(CD3115)
Figure 14 Cable
connections to the Sonar
Control Unit
Note that cable no. 4 (refer to figure 13) is delivered with a
standard length of 100 meters, and has a preconnected plug in
the Sonar Control Unit (wheelhouse) end.
1 Pull cable no.4 from the wheelhouse to the sonar room.
Note that the preconnected plug should be connected to
the Sonar Control Unit in the wheelhouse. Remember to
include the slack for service purpose.
2 The mains power cable (3) may be connected to a normal
mains outlet in the wheelhouse. If the delivered cable does
not fit, put on a suitable connector. Note that the mains
power to the Sonar Control Unit can be 115 VAC or 230
VAC, and that this unit will automatically sense the
voltage.
Kommentare zu diesen Handbüchern