Installation procedures
37
851-160572 / B
In the two last telegrams, the ”True” value is used if both true
and magnetic values are transmitted.
Speed data:
nn.n is speed in Nautical miles
kk.k is speed in Kilometer per hour
The speed value should have min. 1, max. 2 digits in front of
comma, and 1 after. Leading zeroes and spaces are accepted.
Connecting the speed log
The Sonar Control Unit can be connected to a speed log with
one of the following outputs (tick off for the type which will be
connected):
• Pulse log (100, 200 or 400 pulses per nautical mile)
• Serial line (RS-232, RS-422 or 20 mA current loop)
The connection of these different speed log outputs is described
in the following chapters.
Connecting a pulse log
The Sonar Control Unit can be connected to a pulse log with one
of the following outputs (tick off for the type which will be
connected):
• 100 pulses per nautical mile
• 200 pulses per nautical mile
• 400 pulses per nautical mile
For any type of log output (relay, open collector, or
opto-coupler), the output must be free from other connections.
6 7 8 9
FEMALE
(CD1873)
1 2 3 4 5
Figure 23 Connections for a
pulse log with relay output
Figure 23 shows the connection of a pulse log with relay output.
For connection of open collector, or opto-coupler outputs, be
aware of the polarization (see figure 24).